TSC AUTO ID Technology Co., Ltd. 32 Copyright 2009 All Rights Reserved.
LIMITFEED
Description
If the gap sensor is not set to a suitable sensitivity while feeding labels, the printer will not
be able to locate the correct position of the gap. This command stops label feeding and
makes the red LED flash if the printer does not locate gap after feeding the length of one
label plus one preset value.
Syntax
LIMITFEED n (inch, the English system)
LIMITFEED n mm (mm, the metric system)
Parameter Description
n The maximum length for sensor detecting.
Note:
The setting will remain resident in memory.
The default value is 10 inches when printer initializes.
For metric system, there must be a space between parameter n and mm.