ZED-F9P-Integration manual
Figure 56: Base station: u-center data view in TIME mode
C.2 Rover configuration with u-center
This overview will help when setting up a rover when using u-center.
In this procedure, the UART1 is set with an appropriate baud rate for communicating with a host.
Then a set of output messages are set to enable receiver status monitoring.
Using the UBX-CFG-VALSET configuration window in the u-center Message View, set the UART1
interface for the correct host baud rate:
1. Select Group: CFG-UART1, Key name: CFG-UART1-BAUDRATE. See Figure 57.
Figure 57: u-center UBX-CFG-VALSET message view
2. Select Add to List, it will appear in the table below.
UBX-18010802 - R08
Appendix Page 100 of 110
Early production information