MAX-M10M-Integration manual
Controlled software reset terminates all running processes in an orderly manner. Once the
system is idle, restarts the receiver operation, reloads its configuration and starts to acquire
and track GNSS satellites.
Controlled software reset (GNSS only) only restarts the GNSS tasks, without reinitializing the
full system or reloading any stored configuration.
Hardware reset (after shutdown) uses the on-chip watchdog to reset the receiver after
shutdown.
Controlled GNSS stop stops all GNSS tasks. The receiver is not restarted, but stops any GNSS-
related processing.
Controlled GNSS start starts all GNSS tasks.
Table 21 below contains an overview of the different reset types and the data that is cleared.
Reset type Clears RAM Clears BBR
0x00 - Hardware reset (immediately),
0x04 - Hardware reset (after shutdown)
Yes Yes
0x01 - Controlled Software reset Yes No
0x02 - Controlled Software reset (GNSS only),
0x08 - Controlled GNSS stop,
0x09 - Controlled GNSS start
No No
RESET_N pin Yes Yes
Table 21: Overview of the available reset types
3.5 Security
The security concept of MAX-M10M covers:
the integrity of the receiver
communication between the receiver and the GNSS satellites
Some security functions monitor and detect threats and report them to the host system. Other
functions mitigate threats and allow the receiver to operate normally.
3.5.1 Configuration locking
The receiver configuration can be locked so that further changes are no longer possible. The
configuration can be locked by setting the configuration item CFG-SEC-CFG_LOCK to "true". This
item can be set in the same way as all other configuration items on various layers.
If the configuration lock is set in BBR, it remains locked until the BBR is cleared. To test the
function, set it in the RAM configuration layer. After the receiver's power cycle, the information
in this layer is lost and the configuration lock is not set anymore.
3.6 Power management
u-blox receivers support different operating modes. These modes represent strategies of controlling
the acquisition and tracking engines to achieve either the best possible performance or good
performance with reduced power consumption.
3.6.1 Continuous mode
MAX-M10M uses dedicated signal processing engines optimized for signal acquisition and tracking.
The acquisition engine actively searches for and acquires signals during cold starts or when
insufficient signals are available during navigation. The tracking engine continuously tracks and
UBX-22038241 - R02
3 Receiver functionality Page 35 of 92
C1-Public

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox MAX-M10 and is the answer not in the manual?

Ublox MAX-M10 Specifications

General IconGeneral
BrandUblox
ModelMAX-M10
CategoryControl Unit
LanguageEnglish

Related product manuals