EasyManuals Logo
Home>UNI-T>Test Equipment>UPO2000E Series

UNI-T UPO2000E Series User Manual

UNI-T UPO2000E Series
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Others:
+Duty: Ratio of positive pulse width to period.
-Duty: Ratio of negative pulse width to period.
OverSht: (Vmax - Vtop) / Vamp
PreSht: (Vmin - Vbase) / Vamp
Area: Algebraic sum of the voltage and time product of all points on the screen.
CycArea: The area of one period.
Phase: The phase difference between the master source and the slave source.
9.2 Automatic Measurement Menu
Press the MEASURE button on the front panel to enter the automatic measurement menu.
Automatic Measurement Menu (page 1)
Descriptions
Select any of CH1, CH2, CH3, CH4, MATH for automatic
parameter measurement
Close all parameters
Pops up a dialog box of all parameters on the waveform display area
A user-defined parameter selection interface pops up on the
waveform display area, adjust the Multipurpose knob to select
and press the knob to confirm to show the parameter on the
screen.
Press the user defined key again to close the
user-defined parameter dialog box.
Close measurement statistical function.
Automatic calculates and displays the current user defined
parameters of the average, maximum, and minimum.
Only applicable when user defined parameters are present.
Options
Ch1, CH2, CH3,
CH4, MATH
Off
On
Off
Peak
Automatic calculates and displays the current user defined
parameters of the average, standard deviation,
and measurement times.
Only applicable when user defined parameters are present.
Difference
Functions
Signal Source
All Parameters
User Defined
Measurement
Statistical Analysis
Automatic Measurement Menu (page 2)
Descriptions
Select signal source 2 that needs 2 channels for measurement
Adjust the Multipurpose knob to select the parameter indicated
by the indicator among the 34 parameters of automatic
measurement.
Close indicator.
Indicates physical significance of indicator parameters
intuitively by line
Clear all user defined parameters.
Options
Ch1, CH2, CH3,
CH4, MATH
Off
On
Functions
Signal Source
Indicator Selection
Indicator
Clear
48

Table of Contents