F. Duty Cycle Measurement (see figure 8)
(figure 8)
Red Black
Warning
To avoid harms to you or damages to the Meter
from eletric shock, do not attempt to measure
voltages higher than 600V AC/DC, although
readings may be obtained.
The duty cycle range is: 0.1%~99.9%.
To measure duty cycle, connect the Meter as follows:
Insert the red temperature probe into the Hz Duty%
terminal and the black temperature probe
into the COM terminal.
1.
2.
3.
REL
Set the rotary switch to Hz and press to select Duty Cycle measurement
mode.
Connect the test leads across with the object being measured.
The measured value shows on the display.
Model UT203/204: OPERATING MANUAL
28

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT203 and is the answer not in the manual?

UNI-T UT203 Specifications

General IconGeneral
Frequency range0.01 - 1000 kHz
AC current range40 - 400 A
AC voltage range4 - 600 V
Continuity checkYes
DC voltage range0.4 - 600 V
Basic accuracy (frequency)±(0.1%+3)
Basic accuracy (DC current)±(2%+3)
Basic accuracy (DC voltage)±(0.8%+1)
Basic accuracy (resistance)±(1%+2)
Dimensions (WxDxH)76 x 30 x 210 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight200 g