EasyManuals Logo
Home>UNI-T>Multimeter>UT203

UNI-T UT203 User Manual

UNI-T UT203
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
G. DC/AC Current Measurement (see figure 9)
The measuremnet ranges of current are: 40.00
and 400.0 .
To measure current, do the following:
1.
2.
3.
4.
(figure 9)
Set the rotary switch to 40 or 400 . DC
measuremnet mode is a default. Press SELECT to
switch between DC and AC measurement mode.
Hold the Meter tight, don’t release. The Hall
components are very senstive not only to the magnet
but also to heat and machines reaction force. Any
shock will cause the changing in reading in the short
time.
Press the lever to open the transformer jaw.
A
A
A A
Center the conductor within the transformer jaw, then release the Meter slowly until
the trasnformer jaw is completely closed, Make sure the conductor to be tested
is placed at the center of the transformer jaw, otherwise it will casue deviation.
The Meter can only measure one conductor at a time, to meausre more than one
condutor at a time will cause deviation..
40A
400A
Model UT203/204: OPERATING MANUAL
30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT203 and is the answer not in the manual?

UNI-T UT203 Specifications

General IconGeneral
Frequency range0.01 - 1000 kHz
AC current range40 - 400 A
AC voltage range4 - 600 V
Continuity checkYes
DC voltage range0.4 - 600 V
Basic accuracy (frequency)±(0.1%+3)
Basic accuracy (DC current)±(2%+3)
Basic accuracy (DC voltage)±(0.8%+1)
Basic accuracy (resistance)±(1%+2)
Dimensions (WxDxH)76 x 30 x 210 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight200 g