Maintenance (3)
B. Replacing the Battery
Warning
To avoid false readings, which could lead to possible electric shock or personal
injury, replace the battery as soon as the battery indicator "
" appears.
To replace the battery:
1. Turn the Meter to OFF position.
2. Remove the screw from case bottom, and separate the case bottom from the
case top.
3. Remove the battery from the battery compartment.
4. Replace the battery with a new 12V battery (A23).
5. Rejoin the case bottom and case top, and reinstall the screw.
30
Model UT20B: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT20B and is the answer not in the manual?

UNI-T UT20B Specifications

General IconGeneral
Diode testYes
Product typeDigital multimeter
DC current range0.2 - 2 A
DC voltage range0.2 - 300 V
Statistic functionMaximum
Basic accuracy (DC current)±(2.5%+10)
Basic accuracy (DC voltage)±(1.5%+2)
Basic accuracy (resistance)±(2.5%+5)
Dimensions (WxDxH)52 x 26 x 95 mm
Battery voltage12 V
Weight and Dimensions IconWeight and Dimensions
Weight125 g