52
Model UT804: OPERATING MANUAL
Warning
To avoid electrical shock or arc blast, or personal
injury or damage to the Meter, use specified fuses
ONLY in accordance with the following procedure.
Follow Figure 6-1 and proceed as follows to replace
the Meter’s fuse:
l
l
l
l
Switch off the Meter, disconnect the power cord and
remove all connections from the terminals.
Remove the fuse cover from the power socket at the
Meter’s back, then remove the Fuse 3 by gently
prying one end loose, then take out from its bracket.
Use the coin to open the compartment at the case
top, then remove the Fuse 1 and 2 by gently prying
one end loose, then take out from its bracket.
Install ONLY replacement fuses with the identical
type and specification as follows and make sure the
fuse is fixed firmly in the bracket.
Fuse 1: 0.5A, 250V, fast type fuse, ø5×20mm
Fuse 2: 10A, 250V, fast type fuse, ø5×20mm
Fuse 3: 0.2A, 250V, fast type fuse, ø5×20m
Replacement of the fuses is seldom required. Burning
of a fuse always results from improper operation.
l
l
Rejoin the fuse cover and the power socket.
Rejoin the compartment and the case top and close
the compartment.