T-5
TROUBLESHOOTING GUIDE
This guide is a general list of probable problems, causes, and solutions. For problems not
listed or additional questions, contact the Technical Services Department at Vendo, 7209 N.
Ingram Ave., Fresno, CA 93650 or call 1-800-344-7216, extension 3368. Please have the
manufacturer’s date code and model number of the vendor when you call.
The troubleshooting guide is divided into three columns: Possible Problem, Possible Cause,
and Service Suggestion.
POSSIBLE PROBLEM POSSIBLE CAUSE SERVICE SUGGESTION
Returns all good coins No power to vendor Check power supply.
No power to changer Check coin mechanism
plugs. Check for faulty
harness wiring (see wiring
diagram for circuit).
Acceptor is out of adjustment
or coin gate is not closed
Check coin mechanism.
Electronic-CREM function:
1.) No power to acceptor
2.) Defective acceptor
2. Check electrical
connections of the
acceptor.
2. Replace acceptor.
Coin paths are dirty Clean acceptor with
approved cleaner. DRY
VERY THOROUGHLY.