Vitoconnect, type OPTO2 and OT2
Rated voltage 12 V
Wi-Fi frequency 2.4 GHz
Wi-Fi encryption Unencrypted or WPA2
Frequency band 2400.0 to 2483.5 MHz
Max. transmitting power 0.1 W (e.i.r.p.)
Internet protocol IPv4
IP assignment DHCP
Rated current 0.5 A
Power consumption 5.5 W
Protection class III
IP rating Ensure IP 20D to EN 60529.
Permissible ambient temperature
Operation 5 to +40 °C
Use in living rooms and boiler rooms (normal ambient conditions)
Storage and transport 20 to +60 °C
Wall power supply
Rated voltage 100 to 240 V~
Rated frequency 50/60 Hz
Output voltage 12 V
Output current 1 A
Protection class II
Permissible ambient temperature
Operation 5 to +40 °C
Use in living rooms and boiler rooms (normal ambient conditions)
Storage and transport 20 to +60 °C
Vitotrol 100, type OT1
Supply voltage Via OpenTherm connecting cable
IP rating IP 20
Permissible ambient temperature
Operation 0 to +40 °C
At relative humidity of 10 to 90 %
Use in living rooms and boiler rooms (normal ambient conditions)
Storage and transport 20 to +55 °C
Specification
Specification
5813605
Appendix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitoconnect OT2 and is the answer not in the manual?

Viessmann Vitoconnect OT2 Specifications

General IconGeneral
BrandViessmann
ModelVitoconnect OT2
CategoryControl Unit
LanguageEnglish

Related product manuals