30 D-302754
4.11 USER FUNCTIONS
This mode provides you with a gateway to the user functions
through the regular user programming menu. You may:
Program the 4 (private) telephone numbers
Program user codes
Enroll keyfobs
Enroll proximity tags
Select the voice option
Set the auto arm option
Set arming time
Set the squawk option
Set the system time and time format
Set the date and date format
Set the time scheduler
Refer to the User Guide for detailed procedures.
Caution! If after having programmed the user codes the
system does not recognize your installer code, this
indicates you must have programmed a user code that is
identical with your installer code. If so, access the user
menu and change the code that is identical with your
installer code. This will re-validate your installer code.
4.12 RETRIEVING FACTORY DEFAULTS
If you want to reset the PowerMaxComplete parameters to the
factory default parameters, you should enter the installer
menu and perform the "FACTORY DEFLT" function, as
described in the right side illustration. To get the relevant
parameters defaults, contact the PowerMaxComplete dealer.
Note: For PowerMaxComplete with 2 installer codes,
INSTALLER code and MASTER INSTALLER code, only the
master installer code enables to perform factory default
function.
12. FACTORY DEFLT
[installer code]
<OK> to restore
ENTER CODE:
PLEASE WAIT ...
Entering to/exit from the FACTORY
DEFLT menu is shown in figure 4.1a
This is a brief display after which all
the factory defaults are retrieved.
4.13 SERIAL NUMBER
The menu "13. SERIAL NUMBER" enables reading the
system serial number for support purposes only. Clicking
enables reading the version of the
PowerMaxComplete unit.
4.14 CALLING UPLOAD/DOWNLOAD SERVER
Note:
This option is only used during the installation of panels
monitored by compatible central stations.
This option allows the installer to initiate a call to the
upload/download server. The server uploads the
PowerMaxComplete configuration to its data base and can
unload predefined parameters to the PowerMaxComplete.
USER SETTINGS
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
5. DEFINE COMM
[installer code]
INSTALLER MODE
4. DEFINE PANEL
COMMUNICATING TEL # NOT DEFINED
DOWNLOADING DIAL ATTEMPT FAIL
DOWNLOAD OK DOWNLOAD FAILED
Displayed during
dialing process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
Dialing
OK
Dialing
failed
Download
OK
Download
failed
Displayed during
download process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by happy
(success) melody
8. DEFINE OUTPUTS
9. DEFINE VOICE
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT
READY 00:00
P1 RDY 00:00
Non-Partition
mode
Partition
mode
WALK TEST
READY 00:00
(First display)
Figure 4.14 – Start UL/DL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAXCOMPLETE - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMAXCOMPLETE - INSTALLER GUIDE Specifications

General IconGeneral
BrandVisonic
ModelPOWERMAXCOMPLETE - INSTALLER GUIDE
CategorySecurity System
LanguageEnglish

Related product manuals