14 D-302754
4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES & PARTITION
This mode allows you to assign one of 15 zone types to
each of the system's 30 (wireless & wired) zones. You can
define zones as KEY ZONES, to enable arming/disarming
of the system by PowerCode transmitters (see Appendix
E9) In addition, it also allows you to assign a name and
partition number (up to three in a PowerMaxComplete
Partition system) to each zone and determine whether the
zone will operate as a chime zone (only while the system is
in the disarmed
or Home arming state). When a chime zone
is triggered, chime melody or zone name is heard (there are
3 selectable chime modes - Melody chime, Zone Name
Chime or Chime Off).
A list of factory defaults is printed in table 1. You may fill
out the blank columns even before you start and proceed
to program according to your own list.
Remember!
A delay zone is also a perimeter zone by definition.
Zone types are fully explained in Appendix E.
Note: Custom Zone Name text can be changed through
the DEFINE VOICE menu.
ZONE No: - -
Zxx: TYPE -
[Zone No.] (e.g. 05)
1. Inter-follow
2. Perimeter
Zxx: NAME - -
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
(*)
(*)
4. Delay 1
5. Delay 2
6. 24h silent
7. 24h audible
8. Fire
9. Non-alarm
10. Emergency
3. Perim-follow
(see list above)
11. Gas
12. Flood
13. Interior
3. DEFINE ZONES
[installer code]
USER SETTINGS
ENTER CODE
2.
ENROLLING
INSTALLER MODE
<OK> TO EXIT
15. PARTITIONING
14. Temperature
15. Home/Delay
Zxx: CHIME
Zone name-chime
Melody-chime
Chime off
(*)
Zxx: PARTITION
Z05: P1 P2 P3
(*)
(see note)
Zxx: KEY ON/OFF
z-key enable
z-key disable
(*)
(**)
OPTIONAL
If Non-alarm is selected
WALK TEST
READY
First display
[Zone No.] (e.g. 05)
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet (
UK:
Conservatory)
Den (
UK:
Playroom)
Selectable Zone Names
Dining room
Downstairs
Emergency
Fire
Front door
Garage
Garage door
Guest room
Hall
Kitchen
Laundry room
Living room
Master bath
Master bdrm
Office (
UK:
Study)
Upstairs
Utility room
Yard (
UK:
Garden)
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
31 zone names can be selected, 26 fixed names and 5 custom names (defined by
the installer - see chap. 4.9):
Figure 4.3 - DEFINE ZONES Flow Chart
* The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click
or button, until the desired option is displayed, then click (a dark box will be displayed
at the right side).
** Key ON/OFF is an optional function that enables you to arm or disarm the system via zones 21-28, 29 or 21-29,
provided that "non-alarm" was pre-defined for these zones.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAXCOMPLETE - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMAXCOMPLETE - INSTALLER GUIDE Specifications

General IconGeneral
BrandVisonic
ModelPOWERMAXCOMPLETE - INSTALLER GUIDE
CategorySecurity System
LanguageEnglish

Related product manuals