Shutdown
Temporary decommissioning 14.1
53
[us] | 06/2020 | 5100056974 | AS | Operator’s manual
14 Shutdown
14.1 Temporary decommissioning
Information
Further information and detailed descriptions, see Maintenance on
page 45.
14.1.1 Machine
In order to avoid possible damage, the following points must
be observed:
• Always store the machine, rechargeable battery and charger sepa-
rately.
• Do not store near any flammable materials.
• Do not store outdoors.
• Store dry and free of dust.
• Protect from direct sunlight.
• Protect against freezing temperatures. Observe storage temperature
range, see Technical data on page 56.
• Store in a locked place that is not accessible to children.
14.1.2 Accumulator
NOTICE
Property damage due to self-discharge of the accumulator
The self-discharge rate is approx. 3 % per month. Deep discharge can
cause damage to the cells or loss of capacity.
► Store the accumulator with a charge condition of approx. 30 %.
► Check charge condition every six months.
► Charge the rechargeable battery.
14