Initial Setup and Overview G 14
30 wc_tx001185gb.fm
3.4 Battery
Location and
description
A battery is not supplied with the machine. See Technical Data for recommended
battery specifications. Install the battery behind the access panel at the rear of the
machine and secure it with the retaining bracket.
Battery
connections
To connect the battery:
Connect the positive (+) battery cable to the battery.
Connect the negative (-) battery cable to the battery.
To disconnect the battery:
Stop the engine.
Place all electrical switches in the OFF position.
Disconnect the negative (-) battery cable from the battery.
Disconnect the positive (+) battery cable from the battery.
Maintaining
the battery
Follow the battery manufacturer’s maintenance recommendations.
Keep battery terminals clean and connections tight.
When necessary, tighten the cables and grease the cable clamps with
petroleum jelly.
Maintain the battery at full charge to improve cold weather starting.
wc_gr006283
WARNING
Explosion hazard. Batteries can emit explosive hydrogen gas.
f Keep all sparks and flames away from the battery.
f Do not short-circuit battery posts.
WARNING
Battery fluid is poisonous and corrosive.
f In the event of ingestion or contact with skin or eyes, seek medical attention
immediately.