Troubleshooting
Troubleshooting 8.1
77
[en-US] | 09/2022 | 5100061327 | RTLx-SC3 | Operator’s Manual
Problem /
Symptom Reason Remedy
No vibration Machine in high speed travel mode Reduce machine speed, then press vibration
switch.
Faulty vibration switch or poor connection in-
side transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on vibration valve Repair or replace.
Damaged exciter assembly Repair or replace.
Damaged exciter motor coupling Repair or replace.
Damaged exciter motor Repair or replace.
Damaged exciter pump Repair or replace.
Machine out of infrared signal range Move transmitter closer to machine.
Operator too close to machine Move away from machine.
Communication fault
See topic Communication Faults. [}45]
No travel, or
travel only in
one direction
Faulty forward/reverse switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on travel valve Repair or replace.
Damaged drive gearcase assembly Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged drive motor Repair or replace.
Damaged drive pump Repair or replace.
Machine out of infrared signal range Move transmitter closer to machine.
Operator too close to machine Move away from machine.
Communication fault
See topic Communication Faults. [}45]
No high speed
travel
Faulty forward/reverse switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on manifold Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged exciter pump Repair or replace.
Vibration is turned on Turn off vibration.
Machine out of infrared signal range Move transmitter closer to machine.
Operator too close to machine Move away from machine.
Communication fault
See topic Communication Faults. [}45]
No steering Faulty left/right joystick switch or poor connec-
tion inside transmitter
Check connection; repair or replace as needed.
Inoperative solenoid on steering valve Repair or replace.
Loose, broken or corroded wire connections in-
side control panel or transmitter
Repair or replace.
Damaged steering cylinder Repair or replace.
Locking bar engaged Disengage locking bar.
Machine out of infrared signal range Move transmitter closer to machine.
Operator too close to machine
See topic Communication Faults. [}45]
8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RTLx-SC3 and is the answer not in the manual?

Wacker Neuson RTLx-SC3 Specifications

General IconGeneral
BrandWacker Neuson
ModelRTLx-SC3
CategoryConstruction Equipment
LanguageEnglish

Related product manuals