37
Tip Flow volume in l/min*
ø mm ø inch (“) Spray angle at 70 bars at 100 bars at 150 bars
0.18 0.007 10-20-50° 0.16 0.19 0.26
0.23 0.009 10-20-40-50-60° 0.23 0.26 0.30
0.28 0.011 10-20-40-50-60-80° 0.30 0.38 0.47
0.33 0.013 10-20-40-50-60-80° 0.45 0.57 0.69
0.38 0.015 10-20-40-50-60-80° 0.61 0.72 0.91
0.46 0.018 20-40-50-60-80° 0.95 1.14 1.40
0.53 0.021 20-40-50-60-80° 1.25 1.56 1.90
0.66 0.026 20-40-50-60-80° 1.90 2.32 2.80
0.79 0.031 40-50-60-80° 2.84 3.50 4.20
0.91 0.036 40-50-60-80° 3.79 4.56 5.50
1.10 0.043 50-60-80° 5.69 6.84 8.30
1.30 0.052 50° 7.60 9.12 11.10
Flow volume table
*Flow volume refers to water.
g
Bore Spray width at about 30 cm Flat jet
Tip marking mm removal of spray object Use adjusting tip
Pressure 100 bar (10 MPa) Order no.
15 0.13 - 0.46 5 - 35 cm Paints 0999 057
20 0.18 - 0.48 5 - 50 cm Paints, fillers 0999 053
28 0.28 - 0.66 8 - 55 cm Paints, dispersions 0999 054
41 0.43 - 0.88 10 - 60 cm Rust protection
paints - dispersions 0999 055
49 0.53 - 1.37 10 - 40 cm Large-area coats 0999 056
Contact protection
for the flat jet adjustment tip
Order no. 0097 294
Tip extension
with
slewable knee joint
(without tip)
Length 100 cm Order no. 0096 015
Length 200 cm Order no. 0096 016
Length 300 cm Order no. 0096 017
Tip extension
Length 15 cm Order no. 0999 320
Length 30 cm Order no. 0999 321
Length 45 cm Order no. 0999 322
Length 60 cm Order no. 0999 323
Maintenance and cleaning of Airless spray tips
Standard tips
If a different tip type has been fitted, then clean it according to manufacturer’s instructions.
The tip has a bore processed with the greatest precision. Careful handling is necessary to achieve long durability.
Do not forget the fact that the hard-metal insert is brittle! Never throw the tip or handle with sharp metal objects.
The following points must be observed to keep the tip clean and ready for use:
1. Open the relief valve (valve position k).
2. Switch off unit.
3. Dismount the tip from the spray gun.
4. Place tip in an appropriate cleaning agent until all coating material residue is dissolved.
5. If there is pressure air, blow out tip.
6. Remove any residue by means of a sharp wooden rod (toothpick).
7. Check the tip with the help of a magnifying glass and, if necessary, repeat points 4 to 6.
Spray gun accessories
Flat jet adjusting tip
up to 250 bar (25 MPa)