Operating manual Manual Powder System SPRINT XE
6 Assembly and Commissioning
32 Order number 2354920 | Edition 01/2023
6.6.1 Grounding the powder coating system
1 Only use mains cables with grounding strand!
2 Connect the trolley's grounding cable to the grounding connection of the control unit!
3 Connect the control unit's grounding cable with the signal ground!
4 Connect grounding cable to an uncoated metal part of the booth!
5 Remove all paint from hooks and other hanger parts!
6 Wear electrostatically conductive gloves!
7 Wear electrostatically conductive footwear!
8 The floor must be electrostatically conductive!
6.7 SAFETY CHECKS
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4 Carry out safety checks in accordance with Chapter Safety Checks [845].