14. Trouble-Shooting
If you run into any problems with your Pulse, please consult the checklist below. Many
perceived errors are just minor oversights that can be corrected quickly. If you still can't
solve the problem, please contact a qualified repair center or Waldorf Product Support. The
address and telephone number are printed on the warranty card.
Error Corrective Action
Change the setting of the Gate In
Polarity parameter.
Pulse Plus only:
The Pulse is playing after powering up
or notes are hanging.
Ensure the parameter values for the
filter's Cutoff and Keytrack are correct.
If you cannot correct the error, call up
the Filter Tune function.
The filter is not tuned properly.
Make sure a modulation is not
influencing a parameter. In this
example, an envelope with a negative
modulation value could be lowering
the filter cutoff frequency.
The device does not respond properly
to the parameter values you have
entered, e.g. the filter significantly
dampens the signal even at maximum
cutoff setting.
Check the MIDI channel setting in the
MIDI Channel parameter. Note that
this parameter is a global parameter
and consequently pertains to all
programs
The device does not respond to MIDI
data.