English | 9 | Disassembly and disposal
48 | 89014383; Version 2 | Operating instructions UC-Serie
9 Disassembly and disposal
9.1 Taking the warewasher out of operation for long production stops
If the warewasher is taken out of operation for long periods (company holidays, seasonal operation), carry out the follow-
ing steps:
Ø Have the dosing devices rinsed with water by a service technician and allow them to dry. If necessary, observe the
dosing device information provided by third-party manufacturers.
Ø Use the self-cleaning programme to empty the warewasher.
Ø Clean the warewasher.
Ø Open the door.
Ø For Excellence-i(Plus) warewashers: If the period of disuse lasts longer than 28 days, have the membrane of the re-
verse osmosis module preserved by a service technician. Note:The maximum preservation time for the mem-
branes of the reverse osmosis module is 9 months, after which time the preservation must be renewed. In a
preserved state, the warewasher can be stored at temperatures as low as -10 °C.
Ø Switch off the local water supply.
Ø Disconnect the warewasher from the electrical mains supply.
Ø Empty the water treatment unit (e.g. partial demineralisation cartridges).
Ø Instruct an authorised service technician to secure the warewasher against frost.
9.2 Disassembly
Ø Remove any wash items and baskets from the warewasher.
Ø Empty the warewasher completely.
Ø Disconnect the warewasher from the electrical mains supply.
Ø Disconnect the warewasher from the local water supply.
9.3 Disposal
Incorrect or negligent disposal can cause considerable environmental pollution and/or damage.
Ø For hazardous substances, please observe the disposal regulations on the safety data sheets.
Ø Disposal according to national regulations.