3061809_12104
Standards / Regulations
Warnings
- Neverremove,bypassordisablesafetyandmonitoringequipment.
- Only operate the system in perfect technical condition. Immediately
remove/remedyanyfaultsanddamagewhichmayimpactonsafety.
- Alwaysensurethatcoldwaterismixedinwithhotwater,whentheDHW
temperatureis set above60 °C orwhen operating thepasteurisation
system(65°C)(riskofscalding).
Maintenance / Repair
-Regularlychecktheperfectfunctionofallelectricalequipment.
-Onlyqualiedpersonnelmayremovefaultsorrepairdamage.
-OnlyreplacefaultycomponentsorequipmentwithoriginalWolfspare
parts.
-
Alwaysmaintainprescribedelectricalprotectionvalues(seespecication).
AnydamageorlossresultingfromtechnicalmodicationstoWolfcontrol
unitsisexcludedfromourliability.
NB
The boiler control unit complies with the following regulations:
ECDirectives
- 2006/95/EC LowVoltageDirective
- 2004/108/EC EMCGuideline
DIN/ENStandards
EN60335-1,EN60730-2-9,EN14597,
DIN3440,EN50165,EN55014-1
Regarding the installation, observe the following regulations, rules
and directives.
- Theinstallationandcommissioningoftheheatingsystem
- LocalEMCregulations
- DIN VDE 0100 Regulations regarding the installation of high voltage
systemsupto1000V
- DINVDE105Operationofelectricalsystems
- EN50156Electricalequipmentincombustionsystems
- EN12828Heatingsystemsinbuildings
Appropriate use
TheWolfR1controlunitisdesignedexclusivelyforuseinconjunctionwith
Wolfboilers.TheR1controlunitisequippedwithatemperaturecontroller/
limiterandahighlimitsafetycut-out.Thecontrolunitregulatessinglestage
burners.Thesetboilertemperaturecanbeselectedbetween38-90°C.
The R1 control unit can be extended with a BM programming unit for
weather-compensatedtemperaturecontrolwithtimeprogram.
Other applicable documents
Boilerinstallationandoperatinginstructions.
Instructionsforallaccessoriesused.
Installation / Commissioning