Commissioning
SwitchONthesystemON/OFFswitchatthecontrolunit.
ON/OFFswitch
Theheatingsystemstartstooperatewiththefactorysettingsas
soonastheON/OFFswitchatthecontrolunitisswitchedON.
Note:
Thefactorysettingsofthecontrolunitrepresentempiricalvalues.
Subjecttosystemorequipmentlevel,controlparametersother
thanthosechosenatthefactorycanbeselected.Makechanges
viatheWolfcontrol accessories or viaaPC/laptopwithWolf
controlsoftware.Allfactorysettingsarestoredinanon-volatile
memory.
Duringcommissioning,thecontrolunitautomaticallyrecognises
anyconnectedcylinderand/oroutsidetemperaturesensor.
Theoutsidetemperaturesensorisloggedoffbydisconnectionand
byswitchingthesupplyvoltageOFFandONagain.
The system will not be protected against frost if no outside
temperature sensor is connected; only the boiler is frost
protected.
You can log off the cylinder sensor by disconnecting and
resetting.
Theboilersensorcannotbeloggedoff.