Low Battery
Red LED flashes
once every 60
seconds.
1 beep every
60 seconds
The alarm
gives
Independent
Warning.
Malfunction
Red LED flashes
twice every 40
seconds.
2 beeps every
40 seconds
The alarm
gives
Independent
Warning.
Silence Mode
If you press the silence button during an alarm state, the unit will be in the silence mode for 9 minutes.
During the silence mode, the red LED will flash once every 5 seconds. The alarm will enter the normal
mode after 9 minuets.
NOTES
1. Mute all other interconnected alarms by pressing the silence button on the initiating smoke
alarm. But the initiating smoke alarm can
t be silenced by pressing the silence button of any
other interconnected alarm.
2. Under interconnected condition, the initiating smoke alarm can’t be triggered again during
the 9-minute silence duration. But other interconnected alarms can be triggered when
detecting dangerous smoke levels during the silence mode.
Technical Specifications
Power Supply
10-year sealed lithium battery
Sensor Type
Photoelectric
Safety Standards
EN 14604:2005+AC:2008
Standby Current
< 15 uA
Alarm Current
< 150 mA
Coverage Area
20-40 m
2
Best Operating Ambient
Temperature
4.4-37.8 ℃
Operating Relative
Humidity
≤ 85% (non-condensing)
Alarm Loudness
≥ 85 dB at 3 m @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration
About 9 minutes
Operating Frequency
868 MHz
Maximum Number of
Interconnected Units
24 wireless units (Only compatible with X-SENSE wireless
smoke alarms)