46
4.4 Group F auxiliary function parameters
4.4.1 Group F0
Function
code
Description
Function
code
Description
F0-00
Alarm clear
F0-08
Panel external instruction
auto-tuning
F0-01
Resume to default settings
F0-09
Panel internal instruction
auto-tuning
F0-02
Clear the position offset
F0-10
Panel vibration suppression 1
F0-04
Clear up historical alarm records
F0-11
Panel vibration suppression 2
F0-07
Panel inertia identification
F0-12
Panel vibration suppression (fast
FFT)
1. Alarm clearF0-00
Setting F0-00=1 can reset the alarm status. When an alarm occurs, please first eliminate the cause of
the alarm, and then clear up the alarm.
2. Resume to default settingF0-01
Set F0-01=1 when enabler is shut down, press ENTER to resume to default settings, no need to cut
power.
3. Clear the position offsetF0-02
Set F0-02=1 to clear the offset.
4. Clear up historical alarm recordsF0-04
Set F0-04=1 can clear up historical alarm records from U1-14 to U1-53.
5. Panel inertia identification F0-07
Refer to panel inertia identification operation steps chapter 6.3.4.
6. Panel external instruction auto-tuningF0-08
Refer to external instruction auto-tuning chapter 6.5.5.
7. Panel internal instruction auto-tuningF0-09
Refer to internal instruction auto-tuning chapter 6.5.4.
8. Panel vibration suppressionF0-10, F0-11
Refer to vibration suppression chapter 6.7.4.
9. Panel vibration suppression (F0-12)
Refer to vibration suppression chapter 6.7.6.
4.4.2 Group F1
Function
code
Description
Function
code
Description
F1-00
Jog run
F1-04
Tref (torque analog) zero-correction
F1-01
Test run
F1-05
Software enable
F1-02
Current Sampling Zero-correction
F1-06
Reset turns of absolute encoder
F1-03
Vref (speed analog) zero-correction
-
-
1. Test run (F1-01)
Before entering the test run mode, please confirm that the motor shaft is not connected to the
machine!

Table of Contents