Lifting points
The following images show the lifting points for the different installation types. For more
information about the installation types, see Installation on page 18.
Figure 1: P-, T-, X-, and L- installation
Figure 2: S- and F-installation
Figure 3: Z-installation, with hydraulic unit
Figure 4: Z-installation, without hydraulic unit
Lifting equipment
Lifting equipment is always required to handle the unit. The lifting equipment must fulfill
the following requirements:
• The minimum height between the lifting hook and the floor must be sufficient to lift the
unit. Contact a Xylem representative for more information.
• The lifting equipment must be able to hoist the unit straight up and down, preferably
without the need for resetting the lifting hook.
• The lifting equipment must be correctly anchored and in good condition.
• The lifting equipment must support the weight of the entire assembly. Only authorized
personnel may use the lifting equipment.
• The lifting equipment must be dimensioned to lift the unit with any remaining pumped
media in it.
• The lifting equipment must not be oversized.
CAUTION: Crush Hazard
Over-dimensioned lifting equipment can lead to injury. A site-specific
risk analysis must be done.
2.3 Temperature ranges for transportation, handling and storage
Handling at freezing temperature
At temperatures below freezing, the product and all installation equipment, including the
lifting gear, must be handled with extreme care.
2 Transportation and Storage
Flygt 3102 Installation, Operation, and Maintenance Manual 9