5 Mechanical mounting of the HYDROVAR unit on the motor
5.1 Included mounting material
Included
components
Cable gland Cable gland
Closing gland PTC
Motor
Center-
piece
Terminals
for max.
[mm²]
M M M M M PG PG M M PG
PG
12 16 20 25 40 16 29 12
16
16
29
Cable
diameter
[mm]
3,5-7 4,5-10 7-13 9-17 19-28
9-14 14-25
HV-type
2.1-3.4 f 2 (3) 2 2 3 1 1 1 10
3.5-3.11 f 2 (3) 2 2 3 1 1 1 10
3.15-3.22 e 0 (2)
1 (2) 1 1 1 25
3.30-3.45 e 2 (3) 2 (2) 2 (2)
3 1 1 50
( ) max. available cable entries
5.2 Optional components
5.2.1 Fittings
Mounting clamps for motor-mounting
4 pieces per set
(only available for HV 1.15-3.11f)
Mounting ring
Available for the diameters: 140 mm
155 mm
CAUTION!
If you use a motor with plastic fan cover, you have to use a steel mounting
ring.
Distance-bushes
Distance - bushes which are mounted between the HYDROVAR and the motor fan
cover. Different bushes are available, which depends to the output and the type
of the motor. (only necessary for the types HV 3.15-3.22e)