model no. 054-5752-2 | contact us: 1.866.523.5218
32
PROBLEM POSSIBLE CAUSE SOLUTION
Bar and chain
running hot and
smoking.
1.
Check chain tension for
overtightened condition
.
1.
Tension the chain. Refer to Chain
Tension earlier in this manual.
2.
Bar lube reservoir empty
. 2.
Check the bar lube reservoir.
Motor runs, but
chain is not
rotating.
1.
Chain tension too tight.
1.
Re-tension the chain. Refer to
Chain Tension earlier in this manual
.
2.
Check the guide bar and
chain assembly.
2. Refer to Replacing the Bar and
Chain earlier in this manual
3.
Check the guide bar and
chain for damage.
3. Inspect guide bar and chain for
damage.
Troubleshooting