ZXR102900ESeriesCongurationGuide
OAMLinkControlEventCongurationInstance
lCongurationDescription
OAMmonitorfunctioncannotifytheabnormalframeofthelinkreceivertothelocal.
ThefunctionisbasedonOAMdiscovery.AsshowninFigure4-46,Theuserlogsinto
theswitchthroughconsoleportandconguresOAM.EnableOAMandtheportlink
monitoroftheotherend.Thentheerrorframeandtheerrorsymbolcanbedetected
andannouncedtolocalswitch.
Figure4-46LinkControlNetwork
lCongurationProcedure
1.CongurationofswitchA:
zte(cfg)#setethernet-oamenable
zte(cfg)#setethernet-oamport2enable
2.CongurationofswitchB:
zte(cfg)#setethernet-oamenable
zte(cfg)#setethernet-oamport1enable
zte(cfg)#setethernet-oamport1link-monitorenable
zte(cfg)#setethernet-oamport1linsymbol-periodthreshold10window10
zte(cfg)#setethernet-oamport1linframethreshold10window20
zte(cfg)#setethernet-oamport1link-monitorframe-periodthreshold5
window1000
zte(cfg)#setethernet-oamport1link-monitorframe-secondsthreshold10
window30
zte(cfg)#showethport1link-monitor
LinkMonitoringofPort:1
ErroredSymbolPeriodEvent:
SymbolWindow:10(millionsymbols)
ErroredSymbolThreshold:10
TotalErroredSymbols:0
LocalTotalErroredEvents:0
RemoteTotalErroredEvents:0
ErroredFrameEvent:
PeriodWindow:20(s)
ErroredFrameThreshold:10
TotalErroredFrames:0
LocalTotalErroredEvents:0
RemoteTotalErroredEvents:0
4-116
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential