INSTALLATION
16 Residenal Hybrid Electric Heat Pump Water Heater Use and Care Guide

The water heater is now ready for
normal operation. To keep your water
heater working safely and efficiently
and extend its life, perform mainte-
nance as described in maintenance
section beginning on page 26.

NOTE: The default operang mode is
Hybrid, to select a dierent mode see
“Operang Mode Descripons” secon
on page 17.
PRIOR TO BEGINNING OPERATION:
Air lter is factory installed with tabs
oriented down for shipping. Please see
maintenance secon for instrucons on
removal, cleaning and replacing.
1
Turn on electrical power to the
water heater.
 The water heater will conduct
a system diagnosc (approximately 8
minutes) each me power is applied
from an o state. Normal operaon will
begin aer the system diagnosc has
been completed..
2
Once the diagnosc sequence
has nished, the fan should
turn on. This typically takes 8
minutes, (the User Interface Module
will display “-”, “--”, “---” repevely
during this period).
 The heat pump’s fan will not
turn on if the incoming water tempera-
ture is less than 59°F/15°C and/or the
ambient air temperature is above
120°F/15°C, or below 45°F/7.2°C.
Should the internal diagnoscs detect a
problem with the heat pump, an error
code will be displayed.
3
Set the desired operaonal
mode. For typical installaons,
the factory default mode,
Hybrid Mode oers the best combina-
on of eciency and hot water delivery.
For detailed descripons of all opera-
onal modes see “Operang Mode
Descripons” page 17.


Temperature
With the installaon steps completed,
you may adjust the water heater’s tem-
perature seng if desired.
1
The water heater’s tempera-
ture seng has been factory
set to approximately
140°F/60°C. Higher tank temperatures
(140° F/60° C) kill bacteria that cause a
condion known as “smelly water” and
can reduce the levels of bacteria that
cause water-borne diseases.


A mixing Valve must be installed where
required.
Figure 23 - Adjust Thermostat Mixing
Valves to120°F or lower.
-

The water temperature setting
can be adjusted by using the Up
and Down buttons on
the UIM (User Interface Module).
Using the up or down buttons, cycle
through the available temperature
set points until the desired tempera-
ture is displayed. The temperature
setting will blink on the display;
press the Mode/Enter button to
confirm the selection (see figure 26
on page 19).
The available temperature set points
can be cycled through quickly by
pressing and holding the Up button.
2
Please allow adequate me for
the heater to provide hot
water.

-


3
Check water temperature at
several points of use in your
home (for example, bathtub
faucet, shower, or lavatory sink) and
adjust the temperature as needed. If
you aren’t sure how to adjust the
Thermostac Mixing Valve sengs, or
aren’t sure if you have Thermostac
Mixing Valves, contact a qualied
person.
INSTALLATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith ProLine XE and is the answer not in the manual?

A.O. Smith ProLine XE Specifications

General IconGeneral
CategoryWater Heater
BrandA.O. Smith
ModelProLine XE
Installation LocationIndoor
Energy Factor0.95
Vent TypeDirect Vent
Voltage240V
Warranty6 years
Capacity40 - 100 gallons

Related product manuals