Introduction to the manual 11
Commissioning the drive for a motor in a hazardous area
Commission the drive according to the requirements and limitations set by the application,
the motor manufacturer’s instructions, drive firmware manual, local laws and regulations
and this manual.
Minimum switching frequency
The certificate of the Ex motor typically requires that you set a minimum limit for the output
switching frequency of the drive. Make sure that the Ex motor is operated above the
minimum output switching frequency specified by the motor manufacturer. See chapter
Parameter settings for instructions on how to make the setting.
Target audience
The manual is intended for people who install, start-up, use and service the ATEX-certified
motor thermal protection functions of the drive. Read the manual before working on the
drive. You are expected to know the fundamentals of electricity, wiring, electrical
components, electrical schematic symbols and ATEX/Ex regulations.
Contents
This manual contains information on implementing the ATEX-certified motor thermal
protection functions in the ACS880 cabinet-built drives, as well as the ATEX certification
documents.
This manual consists of the following chapters:
Introduction to the manual introduces this manual, gives safety instructions and other
general information for the reader.
ATEX-certified motor thermal protection function with PTC thermistor relays
(+L513+Q971) describes how the function is used for protecting the motor with PTC
thermistor relays, and provides the related safety data.
ATEX-certified motor thermal protection function with Pt100 relays (+L514+Q971)
describes how the function is used for protecting the motor with Pt100 relays, and
provides the related safety data.
Parameter settings lists the parameters that you have the set for the safety functions.
Technical data contains the technical specifications of the relays, applicable
standards, ATEX compliance markings and certificates.
Circuit diagrams contains example circuit diagrams illustrating the operation and
wiring of the functions.
Related documents
Product manuals (see the inside of the front cover)
Circuit diagrams delivered with the drive
Part lists delivered with the drive
00 ACS880 ATEX cabinet.book Page 11 Tuesday, May 28, 2019 10:25 AM

Table of Contents

Other manuals for ABB ACS880-17

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880-17 and is the answer not in the manual?

ABB ACS880-17 Specifications

General IconGeneral
BrandABB
ModelACS880-17
CategoryDC Drives
LanguageEnglish

Related product manuals