If Profile option
is not fitted
Displayed only
with
Profile
option
Displayed only
with
Timer
option
OPrtOr
LEVEL
bASIC
CONFIG
CONtrl
CONFIG
Basic Config
Control Config
Operator Level
AdV.NCd
CONFIG
Advanced Config
SECOdE
____
Security Code Profile States
PrOFILE
StAtES
Program Select
Run/Hold
PrOGrM
____
rS____
____
Profile Reset
rESEt
__
Skip Segment
SEG __
SKIP–x
Control Page
Prop. Band Heat
CONtrL
PAGE
PrOP
h___._
Cycle Time Heat
Manual Reset Heat
Cycle Time Cool
_rESEt
h___._
CYCt
c___..
Integral Time Heat
CYCt
h _..
INtGrL
h____
Integral Time Cool
Approach Band
INtGrL
c____
APPb
_._
Man. Reset Cool
Transition Band
Off Hysteresis
t-bANd
___._
OFFhYS
__._
Crossover D.P. Value
_rESEt
c____
CrSOU.r
___._
Derivative Action
dErIU
___..
Prop. Band Cool
PrOP
c___._
PV & SPT
ACKNLG
ALArMS
Acknowledge Alarms
Alarm Identity/Type
Tota lized Value
Reset Total
Stop/Go
8888
8888
Output
Manual Reset
tOtALS
PAGE
rESEt
t1___
COUNt1
____
Tota l 1
____
OP____
____
r___._
A-HPrC
____
____
____
PV & Units
____
dEG F
Set Point Type
______
______
Set Point Ratio
Set Point Bias
rAt10
1.000
bIAS
0
Segment/Time
SEG __
t_____
Repeat Counts
rPt-Ct
____
Time
tI_E
____
Date
dAtE
____
Program/Status
PrG__
____
See Note
If Totalizer on control
channel is off or
Totalizer option is not
fitted
Al
RMT
AT
MAN
100.3
200.5
Control Faceplate
Heat/Cool Control Pages
Faceplate 2
Faceplate 1 only
rESEt
t2___
____
____
Stop/Go
COUNt2
____
OR
Operating Page
Section 5.2, Page 13
Alarm Acknowledge Page
Section 5.3.3, Page 16
Totals Page
Section 5.4, Page 17
Security Code Page
Section 5.5.1, Page 18
Profile States Page
Section 5.6, Page 19
Control Page
Section 5.10.1, Page 32
Displayed on
Faceplate 1
Displayed on
Faceplate 2
Displayed only if
enabled in the
Set
Up Operating Page,
CONTROL
CONFIGURATION
LEVEL
Tota l 2
______
ISS _
EPROM Identity
5 CONTROL OPERATION…
Note. The Alarm Acknowledge pages are displayed only if an alarm is active.
Fig. 5.2 Summary of Operating Level Frames (Heat/Cool Control)

Other manuals for ABB C1900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB C1900 Series and is the answer not in the manual?

ABB C1900 Series Specifications

General IconGeneral
BrandABB
ModelC1900 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals