6 Mounting / Installation
Pos: 80 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Sic herheit (--> Für alle Dokum ente <--)/Warnhinweis e/Sicherheit - Ni ederspannu ngs- und 230 V-L eitungen @ 18\mod_13 02617821491_15. docx @ 10346 5 @ @ 1
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
– Low-voltage and 100-240 V cables must not be installed together in
a flush-mounted socket!
In case of a short-circuit there is the danger of a 100-240 V load on
the low-voltage line.
Pos: 81 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Sic herheit (--> Für alle Dokum ente <--)/Warnhinweis e/Sicherheit - F achkenntniss e @ 18\mod_13 02774384017_ 15.docx @ 1 03564 @ 2 @ 1
6.1 Requirements for the electrician
Install the device only if you have the necessary electrical engineering
knowledge and experience.
• Incorrect installation endangers your life and that of the user of the
electrical system.
• Incorrect installation can cause serious damage to property, e.g.
due to fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth;
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
to ground, protective earthing, necessary additional measures,
etc.).
Pos: 82 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Mont age/Montage hinweise - Allge mein @ 19\ mod_13105636 70478_15.doc x @ 107743 @ 2 @ 1