5 - Installation
2. WEIDMÜLLER WM4 quick-t connectors
Installation of Weidmüller WM4 connectors requires crimping to be carri-
ed out with suitable equipment.
- Strip the cable to which you want to apply the connector (after verifying
that it complies with the connector limits).
- Apply the terminal to the conductor using the designated pliers.
Weidmüller
CTF PV WM4
(1222870000)
- Insert the cable with the terminal into the interior of the connector, until
you hear the click indicating that the terminal is locked inside the con-
nector.
- Firmly tighten the cable gland using the relevant tool to nish the ope-
ration.
2.0÷2.5 Nm
WEIDMÜLLER
SET MULTI-TOOL PV
(1217280000)
7mm
4...6mm
6...7mm
2