Operation Manual / TPL67-C.. - TPL71-C..
Taking out of operation at short notice
Possibilities for emergency repair
Page 105
ABB. All rights reserved.
April 2016 HZTL2488_EN Revision C
Taking out of operation at short notice
Possibilities for emergency repair
9.1
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe personal
injury or fatal accidents can result.
Cordon off danger area.
Sound an alarm and depending on the situation, stop the engine.
Seal oil leaks.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as possi-
ble after damage to the turbocharger (emergency repair), the following
possibilities are available:
Locking turbocharger rotor
Fitting the cover plate
Shutting off inlets and outlets
Turbocharger bypass