Operation Manual / TPL67-C.. - TPL71-C..
Taking out of operation at short notice
9
Possibilities for emergency repair
9.1
Page 105
© Copyright 2016
ABB. All rights reserved.
April 2016 HZTL2488_EN Revision C
Taking out of operation at short notice
Possibilities for emergency repair
9.1
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe personal
injury or fatal accidents can result.
Cordon off danger area.
Sound an alarm and depending on the situation, stop the engine.
Seal oil leaks.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as possi-
ble after damage to the turbocharger (emergency repair), the following
possibilities are available:
Locking turbocharger rotor
Fitting the cover plate
Shutting off inlets and outlets
Turbocharger bypass
9
9.1

Table of Contents

Other manuals for ABB TPL-C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB TPL-C Series and is the answer not in the manual?

ABB TPL-C Series Specifications

General IconGeneral
BrandABB
ModelTPL-C Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals