Operation Manual / TPL67-C.. - TPL71-C..
Malfunctions during operation
Page 69
© Copyright 2016 ABB. All rights r
eserved.
April 2016 HZTL2488_EN Revision C
Malfunctions during operation
6.3
Lubricating oil pressure too low
Engine Oil filter heavily contaminated Clean it
Defective oil pump in lubricating
system
Manometer display wrong Replace the manometer
ger
Rotor axial clearance too large
Contact an ABB Turbocharging
Service Station
Defects of connected cylinders
when pulse charging
Contact the enginebuilder
Turbochar-
ger
Heavy contamination of the tur-
bine
Clean it
Damaged rotor components or
bearing
Contact an ABB Turbocharging
Service Station
Pipes Defects such as leaks in the
exhaust gas pipes or charge air
ducts
Make repairs
Turbochar-
ger
Heavily contaminated nozzle
ring (with 4-stroke application)
Contact an ABB Turbocharging
Service Station