INSTALLATION
Vecto r H® S eries ▪ Operat or’s M anual ▪ M N-46 2 95 ▪ Rev 7 ▪ 6/22
23
How to Install the Oven (60 Hz Cord and Plug Models)
Before you begin Make sure you have:
▪ An appropriate lifting device, and enough personnel, to safely move and position
the weight of the oven.
□ VMC-H2/H2H: 213 lb (97 kg)
□ VMC-H3/H3H: 278 lb (126 kg)
□ VMC-H4/H4H: 348 lb (158 kg)
□ VMC-H2HW: 243 lb (110 kg)
□ VMC-H3HW: 312 lb (142 kg)
Requirements ▪ The oven must be installed on a level surface.
▪ The oven must not be installed in any area where it may be affected by steam,
grease, dripping water, high temperature, or any other severely adverse
conditions.
▪ The oven is not intended for built-in installation.
Voltages
Continued on next page
V Ph Hz A Breaker* kW Plug Configuration
VMC-H2/
VMC-H2H
208
240
1
1
60
60
25
28
30
30
5.2
6.7
NEMA 6-30P
NEMA 6-30P
VMC-H3/
VMC-H3H
208
240
208
240
1
1
3
3
60
60
60
60
38
43
22
25
50
50
30
30
7.9
10.3
7.9
10.3
NEMA 6-50P
NEMA 6-50P
NEMA 15-30P
NEMA 15-30P
VMC-H4/
VMC-H4H
208
240
3
3
60
60
33
38
40
40
10.6
13.9
NEMA 15-50P
NEMA 15-50P
VMC-H2HW 208
240
208
240
1
1
3
3
60
60
60
60
33
38
19
22
50
50
40
40
6.9
9.1
6.9
9.1
NEMA 6-50P
NEMA 6-50P
NEMA 15-30P
NEMA 15-30P
VMC-H3HW 208
240
3
3
60
60
29
33
50
50
10.5
13.6
NEMA 15-50P
NEMA 15-50P
*Electrical connections must meet all applicable federal, state, and local codes.