You must be able to turn the turning knob
easily.
Open and remove Secuquick softline with the
turning knob
When open, the yellow marking is visible
completely.
4. Maintenance
and care
Maintain and care for the Secuquick softline as under:
Dismantle and clean after every use.
Check the functioning before next use: valves and
seals, condition of the lid clip.
Replace sealing ring and other seals if they are
damaged, cracked, shrunken or torn. These parts
should be replaced at least every 2 years.
Use only original spare parts meant for the Model 4200.
4.1 Dismantling Secuquick softline
Unscrew bellnut (6)
Remove bottom lid (7) from the top lid (8)
15
6
7
8