33
SERVICE
PARAMETERS
DESCRIPTION OF PARAMETERS
Parameter Description
Default
(IS...)
Default
(IA...)
Default
(DS...)
min MAX
POSITIVE QUICK COOLING
P01 Room SetPoint in pos. quick cooling, Soft phase -5°C -5°C -5°C -30°C 30°C
P02 SetPoint cella in abbattimento Hard -25°C -25°C -25°C -40°C 30°C
P03 Needle SetPoint in pos. quick cooling , Soft phase 3°C 3°C 3°C -30°C 30°C
P04 Needle SetPoint in Hard quick coolong 20°C 20°C 20°C -30°C 30°C
P05 Positive quick cooling duration 90min 90min 90min 0min 900min
P06 Hard phase duration expressed as % in relation to P05 60% 60% 60% 0% 100%
P07 Room SetPoint in pos. storing 2°C 2°C 2°C -30°C 30°C
NEGATIVE QUICK COOLING
N01 Room SetPoint in neg, quick cooling -25°C -25°C -25°C -40°C 30°C
N02 Needle SetPoint in neg. quick cooling -18°C -18°C -18°C -30°C 30°C
N03 Negative quick cooling duration 240min 240min 240min 0min 900min
N04 Room SetPoint in neg. storing -22°C -22°C -22°C -40°C 30°C
A
LARMS
A
01
T
emperature alarm hysteresis 2°C 2°C 2°C 0°C 10°C
A02
High temperature limit alarm in pos. storing in relation
to P07
10°C 10°C 10°C 0°C 50°C
A03
Low temperature limit alarm in pos. storing in relation
to P07
-10°C -10°C -10°C -50°C 0°C
A04
High temperature limit alarm in neg. storing in relation
to N04
10°C 10°C 10°C 0°C 50°C
A05
Low temperature limit alarm in neg. storing in relation
to N04
-10°C -10°C -10°C -50°C 0°C
A
06
T
emperature alarm delay fron storing or defrost start 60min 60min 60min 0min 300min
A
07
T
emperature alarm delay 30min 30min 30min 0min 300min
A
08 Duration of the buzzer in the alarm mode 1min 1min 1min 0min 240min
DISPLAY
D01
T
emperature unit of measurement (0 Celsius; 1 Fahrenheit) 0 0 0 0 1
D02 Room probe Offset 0°C 0°C 0°C -10°C 10°C
D03 BackLight (0 on when pressing a key; 1 always on) 1 1 1 0 1
D04 Heart probe offset -7°C -7°C -7°C -10°C 10°C
D05 Subcutaneous probe offset -7°C -7°C - -10°C 10°C
D06 External probe offset -7°C -7°C - -10°C 10°C
DEFROS
T
S01 Performs defrost on quick cooling start 0 = No; 1 = Ye
s
000 01
S02 End-o
f
-defrost temperature 8°C 8°C 8°C -10°C 30°C
S03* Defrost max. duration 15 min 15 min 15 min 1 min 90 min
S04 Interval between defrosts in storing (0=excluded) 0 ore 0 ore 0 ore 0 18 ore
S05*
T
ype of defrost:
0= electrical or due to compressor stop
1= hot gas
2= air
2 2 2 0 2
S06* Dripping time 1 min 1 min 1 min 0 min 90 min
S07 Compressor activation delay with hot gas defrost 0 sec 0 sec 0 sec 0 sec 600 se
c
S08
First defrost activation time from storing start
(0=excluded)
0 0 0 0 90 min
S09 Ignores compressor protection delays in defrost 0 0 0 0 1

Table of Contents