EasyManuals Logo
Home>Aqua Computer>Water Pump>D5 NEXT

Aqua Computer D5 NEXT User Manual

Aqua Computer D5 NEXT
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
D5 NEXT
17.2.
17.2.17.2.
17.2. Factory defaults
Factory defaultsFactory defaults
Factory defaults
Click the button “Reset device to factory defaults” in the aquasuite or select the
“Factory defaults” entry from the menu for a complete reset of all settings. You will
have to completely reconfigure the device after resetting it to factory defaults!
17.3.
17.3.17.3.
17.3. aquabus/RGBpx configuration
aquabus/RGBpx configurationaquabus/RGBpx configuration
aquabus/RGBpx configuration
Depending on configuration, the bus” connector can either be used for commu-
nication with an aquaero 5/6 or to connect RGBpx products. Simultaneous use of
both functions is not possible!
Before connecting two D5 NEXT pumps simultaneously to an aquaero 5/6 via
aquabus, each pump has to be configured to a unique aquabus address. If only
one device is connected via aquabus, this step may be skipped. Address 30 and
31 are available. Please note that aquastream ULTIMATE and aquastream XT as
well as D5 NEXT share resource assignments in the aquabus device handling of
the aquaero. A combined maximum of two pumps of these types can be managed
by the aquaero.
Changes to the bus address configuration are effective within a few seconds. How-
ever, it may take up to five minutes for a connected aquaero to update its configu-
ration.
17.4.
17.4.17.4.
17.4. Firmware update and language selection (aquasuite only)
Firmware update and language selection (aquasuite only)Firmware update and language selection (aquasuite only)
Firmware update and language selection (aquasuite only)
The most up to date firmware for all supported devices is always included in the
current version of the aquasuite software. The button Update firmware now” will
start the update process for the device firmware.
During the firmware update process, the language of the pump menu will auto-
matically be set to the currently selected language in the aquasuite software. To
change the language of the pump menu, first select the desired language in the
basic aquasuite settings and restart the aquasuite software. Afterwards, perform a
firmware update of the D5 NEXT to change the language of the pump.
During the firmware update process, do not disconnect the device from the PC
and do not power down the PC! After the firmware is successfully updated, the
aquasuite software will be automatically closed.
18.
18.18.
18. Playground (aquasuite)
Playground (aquasuite)Playground (aquasuite)
Playground (aquasuite)
Click the entry “Playground” to configure Virtual Software Sensors, global profile
management and hotkeys.
18.1.
18.1.18.1.
18.1. Virtual Software Sensors
Virtual Software SensorsVirtual Software Sensors
Virtual Software Sensors
Virtual Software Sensors can be used for extensive yet easy to use adapta-
tion and calculation of sensor values using mathematical and logical
functions as well as filters.
- 24 - Aqua Computer GmbH & Co. KG © 2019-2020
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aqua Computer D5 NEXT and is the answer not in the manual?

Aqua Computer D5 NEXT Specifications

General IconGeneral
BrandAqua Computer
ModelD5 NEXT
CategoryWater Pump
LanguageEnglish