6. 2. 3 Offset
Auto Function active
from - 14 to + 14 (°C)
(high temperature)
0
from - 7 to + 7 (°C)
(low temperature)
0
To adapt the heating curve to the system
requirements, shift the curve in parallel so that
the calculated ow temperature is modied, in
addition to the room temperature.
By accessing the parameter and pressing the
button b, it is possible to shift the curve in a
parallel direction. The shifting value can be read
on the display: from -14 to +14 for high-temperature
devices, or from -7 to 7 for low-temperature
devices. Each step corresponds to a 1°C increase/
decrease In the ow temperature with respect to
the set-point value.
6. 2. 4 Room Inuence
Proportional
Auto Function active
from 0 to 20 20
If setted = 0 the room temperature doesn’t
inuence the calculation of the set-point.
If setted = 20, the room temperature has the
maximun inuence to calculate the set-point
- only active when the BUS device is connected
6. 2. 5 Maximum CH
Temperature Zone 3
from 35 to 82 °C
(Param. 620 = 1)
82
from 20 to 45 °C
(Param. 620 = 0)
45
6. 2. 6 Minimum CH
Temperature Zone 3
from 35 to 82 °C
(Param. 620 = 1)
35
from 20 to 45 °C
(Param. 620 = 0)
20
6. 3 Z3 DIAGNOSTICS
6. 3. 0 < Not Available>
6. 3. 4 Heat request Zone 2 0 = OFF
1 = ON
8 SERVICE PARAMETERS
8. 0 BOILER STATISTICS - 1
8. 0. 0 Diverter valve cycles No. (nx10)
8. 0. 1 Time of circulator on (nx10)
8. 0. 2 Boiler circulator cycles No. (nx10)
8. 0. 3 Boiler Life Time (hx10)
8. 0. 4 Time of fan ON (hx10)
8. 0. 5 Fan cycles No. (nx10)
8. 0. 6 CH ame detection (nx10)
8. 0. 7 DHW ame detection (nx10)
8. 1 BOILER STATISTICS - 2
8. 1. 0 Hours Burner On CH (hx10))
8. 1. 1 Hours Burner On DHW (hx10)
8. 1. 2 Number of Flame Faults (nx10)
8. 1. 3 Numbeer of ignition Cycles (nx10)
8. 1. 4 Heat request Duration
8. 2 BOILER
8. 2. 1 Fan Status 0 = OFF
1 = ON
8. 2. 2 Fan Speed - x100 RPM
8. 2. 3 Pump speed - NOT ACTIVE
menu
sub-menu
parameter
description value
default
setings
menu
sub-menu
parameter
description value
default
setings
8. 2. 4 Diverter valve position 0 = D.H.W.
1 = Central Heating
8. 2. 5 D.H.W. Flow Rate (l/min)
8. 2. 7 Pump Modulation %
8. 2. 8 Gas Power (kW)
8. 3 BOILER TEMPERTURE
8. 3. 0 CH Flow set Temperature(°C)
8. 3. 1 CH Flow Temperature(°C)
8. 3. 2 CH Return Temperature(°C)
8. 3. 3 DHW Temperature (°C)
8. 3. 4 < Not Available>
8. 3. 5 Outdoor temperature (°C)
Only with external sensor connected
8. 4 STORAGE
8. 4. 2 D.H.W. Inlet Temperature (°C)
Display only with Solar Kit or external storage Kit
8. 5 SERVICE
8. 5. 0 Months to next
maintenance
from 0 to 60
(month)
24
If setted the boiler will display that is time to call
the installer for maintenance
Semnalare 3P9
intretinere programata
- chemati asistenta tehnica
ALERT
8. 5. 1 Maintenance on Day
At
0 = OFF
1 =ON
8. 5. 2 Maintenance Warning
Reset
Reset? OK= Yes
Esc = No
to erase the advice for maintenance
8. 5. 4 SW version Interface
8. 5. 5 SW version Main
8. 6 ERROR HISTORY
8. 6. 0 Last 10 Errors from Fault 0 to Fault 9
This parameter makes it possible to see the
last 10 errors shown by the boiler as well as the
relevant day, month and year.
Turning the encoder allows for viewing the
sequence of errors that occurred, from 0 to 9.
Fault 3
No flame detected
501
12:18 24/01/2012
8.6.0 Last 10 errors
8. 6. 1 Reset Error List Reset?
Ok=Yes
Esc=No
8. 7 FREE PARAMETERS
8. 7. 4 Boiler Flowswitch 0 = Open
1 = Closed
8. 7. 6 Safety ame sensor
8. 7. 8 Boiler power level
8. 7. 9 Ionization current

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ALTEAS ONE+ NET and is the answer not in the manual?

Ariston ALTEAS ONE+ NET Specifications

General IconGeneral
BrandAriston
ModelALTEAS ONE+ NET
CategoryBoiler
LanguageEnglish

Related product manuals