Installation & Servicing instructions ATAG A-Series
34
3028262422
18
16
14
12
8
6
4
1
heating line Grac 11.4.a
outside temperature in °C
ow temperature in °C
11.5 Activating the factory setting (green button function)
To re-activate the factory settings, proceed as follows (this will undo all changed settings):
- Select P6 81, according to the procedure described in chapter 11.4;
- Select b7;
- Press OK. The screen is showing ‘off’;
- Select ‘on’;
- Press OK.
The screen then shows P6 81 and the factory settings are active again.

Other manuals for Atag A203C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atag A203C and is the answer not in the manual?

Atag A203C Specifications

General IconGeneral
Type-
Fuel typeNatural gas
Boiler systemCombi boiler system
Product colorWhite
Heater locationIndoor
Placement supportedVertical
Boiler type (NL label)HR
HR inspection label class107
Maximum power20000 W
Minimum power4400 W
Water flow (60 °C)6 l/min
Domestic Hot Water (DHW) flow10.7 l/min
Weight and Dimensions IconWeight and Dimensions
Depth395 mm
Width500 mm
Height650 mm
Weight37000 g