Installation & Servicing instructions ATAG A-Series
47
*AllinstallationsinEnglandandWalesmustbenotiedtoLocalAuthorityBuildingControl(LABC)eitherdirectlyorthrougha
CompetentPersonsScheme.ABuildingRegulationsComplianceCerticatewillthenbeissuedtothecustomer.
©HeatingandHotwaterIndustryCouncil(HHIC) www.centralheating.co.uk
It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed.
Service Provider
BeforecompletingtheappropriateServiceRecordbelow,pleaseensureyouhavecarriedouttheserviceasdescribedinthemanufacturer’sinstructions.
Alwaysusethemanufacturer’sspeciedsparepartwhenreplacingcontrols.
SERVICE RECORD
SERVICE 01
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 02
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 03
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 04
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 05
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 06
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 07
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 08
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 09
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature
SERVICE 10
Date:
Engineername:
Companyname:
TelephoneNo:
GassaferegisterNo:
Record:
Atmax.rate: COppm AND CO
²
%
Atmin.rate:
(WherePossible) COppm AND CO
²
%
Comments:
Signature

Other manuals for Atag A203C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atag A203C and is the answer not in the manual?

Atag A203C Specifications

General IconGeneral
Type-
Fuel typeNatural gas
Boiler systemCombi boiler system
Product colorWhite
Heater locationIndoor
Placement supportedVertical
Boiler type (NL label)HR
HR inspection label class107
Maximum power20000 W
Minimum power4400 W
Water flow (60 °C)6 l/min
Domestic Hot Water (DHW) flow10.7 l/min
Weight and Dimensions IconWeight and Dimensions
Depth395 mm
Width500 mm
Height650 mm
Weight37000 g

Related product manuals