14
Runback
Setback
Max. Temp.
Runback
OK
Runback Config.
OFF
ON
Settings
Runback
OK
Status ON
Change
Password
OK
Status
ON
OFF
Password
OK
Status ON
Change
Password
OK
CONFIRM
NEW PASSWORD
1 2 3 4 OK
ENTER NEW
PASSWORD
0 0 0 0 OK
PASSWORD
The Password Function of the Sunray RF
Radiator serves a number of functions; Keylock,
Advanced menu access and also Runback access
when the runback is activated. The Default
password from the factory is four Zero’s (0 0 0
0), however it is strongly recommended that once
installation is complete that an alternative code is
set.
To access the password function enter the
ADVANCED SETTINGS menu and then select
PASSWORD.
The password can be turned on or off and
changed.
To Turn the password on or off, Select Change
and press OK.
Select either ON or OFF and press OK. If you
are reactivating the password then the Enter New
password screen is shown (The password will
always default back to 0 0 0 0).
If the password is turned off, the Keylock,
Advanced Settings menu and Runback controls
are accessible without entering a password.
To Change the password code when the
password is active select Change from the
password screen and press OK.
Enter and conrm the new password and press
OK.
RUNBACK MODE
The Sunray RF Heater comes with a runback
mode for use when the heater will be installed in
areas where restricted user control is required.
When Runback Mode is active it allows the user
to set the radiator to run for a specic pre-set
amount of time and temperature. It is also possible
to set a maximum temperature (Max Temp) above
the Runback setting to allow the user to increase
the temperature within the limits allowed.
Before activating Runback mode it is strongly
recommended that an alternative password is set
and activated and the comfort mode temperature
setpoint is set to 35°C. When the password is
activated the user will have no access to the
radiator settings without the password.
NOTE: Any Display settings will be used in
RUNBACK mode, eg. Backlight time and intensity,
Eco mode etc.
After the runback time period ends the room
temperature will return to off (7°C minimum) until
the runback is restarted.
It is also possible to set a minimum temperature
to be maintained (Setback) outside of the runback
mode; when setback mode is activated the room
temperature will only fall as low as the Setback
temp and be maintained at this point until runback
is restarted.
ACTIVATING RUNBACK MODE
Runback mode is activated
from the Advanced settings
menu.
The main runback screen has
3 options:
• Runback Cong
• Setback Cong
• Max Temp
Set Runback to ON to activate
the mode.