Make sure that there are no people in the danger
zone.
♦
Start the carrier as instructed by the carrier
manufacturer.
♦
Let the carrier warm up until the operating
temperature prescribed by the carrier manufacturer
has been reached.
♦
Put the carrier in its working position.
Switching the hydraulic
demolition cutter on and off
After properly attaching the hydraulic attachment to
the carrier, the hydraulic attachment can be operated
using the carrier's hydraulic system. All functions for
normal carrier operation remain intact.
The hydraulic attachment is switched on and off using
electrical and hydraulic signals.If you have any
questions about electric/hydraulic commands, consult
the carrier manufacturer and/or the Atlas Copco
Customer Center/Dealer in your area.
♦
Switch the hydraulic attachment on and off, as
described in the carrier's operating instructions.
♦
When leaving the driver's cab, set the safety
switch/lever for the electrical/hydraulic attachment
installation to the "OFF" position.
Carry out the above actions to prevent any
unintended start-up of the hydraulic attachment.
Functional test
Always carry out a functional test before putting the
hydraulic demolition cutter into use. Check that all
hydraulic lines and connections are tight and that the
hydraulic demolition cutter works without any
problem.
♦
Prepare the hydraulic demolition cutter so that you
can start using it (see chapter Preparations before
to starting).
♦
Lift the hydraulic demolition cutter with the carrier
boom function so that it hangs vertically.
♦
Close and open the cutter jaws.
♦
Turn the hydraulic demolition cutter via the
connected carrier function »Turn gripper« left
and right.
♦
Observe the hydraulic lines and whether the
hydraulic demolition cutter works properly.
♦
Switch the hydraulic demolition cutter off
immediately if oil leaks from the hydraulic lines or
other malfunctions occur.
♦
Depressurise the hydraulic system (see chapter
Depressurising the hydraulic system).
♦
Only take the hydraulic demolition cutter back into
operation once all leaks or malfunctions have been
remedied.
Correct operation
Demolishing concrete ceilings or walls
♦
Encompass the concrete ceilings and walls as far
as possible with the hydraulic demolition cutter.
In high reinforced concrete structures
♦
First break the concrete with the tip of tooth area.
♦
Then cut the reinforcements with the cutter blades.
Working position
♦
Change the working position in good time.
♦
Start demolition from the narrow sides.
© 2015 Construction Tools GmbH | No. 3390 5141 01 | 2015-11-16
Original instructions
36
CC 1700 U, 1700 SOPERATION