5. If necessary, press the tabulator key (5) to go to the next
field to be modified, the minutes indication and the start/
stop/pressure band indication.
6. Press the key Prog to program the new command or the
key Canc to quit without reprogramming.
13.4 To add a command
Adding a command at the end of an existing list
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Clock function is
followed by a horizontal arrow. Press the tabulator key (5),
following screen appears:
Clock Function
Not activated ®
Menu Mod Del
F1 F2 F3
Suppose the command to stop the compressor at 18:00 must be
added to the list of Monday:
- 06:15 start
- 06:15 band 1
3. Press the tabulator key (5), following screen appears:
Monday ®
Tuesday
Wednesday ¯
Menu Mod Del
F1 F2 F3
4. Scroll through the display until Monday is followed by a
horizontal arrow. Press the tabulator key (5). Scroll through
the compressor start/stop/pressure band commands until the
first empty command line is indicated by the horizontal
arrow on the screen.
5. Press the key Mod, the first two digits of the command
start blinking. Enter 18:00 stop using the scroll keys ¯ or
to modify a field and the tabulator key (5) to jump from
one field to another.
6. Press the key Prog to program the new command or the
key Canc to quit without reprogramming.
Adding a command between two existing commands
1. Suppose the command 17:00 band 2 must be added to
following list:
- 06:00 start
- 06:00 band 1
- 18:00 stop
2. The regulator does not allow to enter a new command which
is situated timewise before the last command in the list.
3. Scroll through the display until the command before which
the new command must be entered is followed by the
horizontal arrow (in the example above: 18:00 stop) and
press the key Mod. Change this command to the new
command (in the example above: 17:00 band 2) and press
the Prog. Press the ¯ key, add the last command of the
list (in the example above: 18:00 stop) and press the key
Prog.
13.5 To delete commands
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Clock function is
followed by a horizontal arrow. Press the tabulator key (5),
following screen appears:
Clock Function
Not activated ®
Menu Mod Del
F1 F2 F3
Deleting all commands
Press the key Del (F3) in the screen above. A question to
confirm the deleting operation will appear.
Deleting all commands related to a specific day
Scroll through the display until the desired day is followed by
a horizontal arrow. Press the key Del (F3). A question to
confirm the deleting operation will appear.
Deleting a specific start/stop/pressure band command
Scroll through the display until the desired start, stop, band 1
or band 2 command line is followed by a horizontal arrow.
Press the key Del (F3). A question to confirm the deleting
operation will appear.