EasyManuals Logo
Home>Atlas Copco>Air Compressor>GA30

Atlas Copco GA30 User Manual

Atlas Copco GA30
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
2920 1461 03
30
User manual
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Service is followed
by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. A screen similar to the one below appears:
Service Timer
Running Hours ®
hrs 7971 ¯
Menu
F1 F2 F3
Fig. 15.1 Service menu
The screen shows that the total compressor running time is 7971
hrs.
3. Press the tabulator key (5):
Next Timer
Level A B C
hrs 8000 ¯
Back Rset
F1 F2 F3
Fig. 15.2 Service menu
The screen shows that the next service plans to be carried out
are plans A, B and C and that these plans are to be carried out
each 8000 running hours.
4. Press the ¯ key to find which service plans were carried out
previously:
Previous Timer
Level A B
hrs 4008
F1 F2 F3
Fig. 15.3 Service menu
The screen shows that service plans A and B were carried out
at 4008 running hours.
5. Stop the compressor, switch off the voltage and carry out
the service operations related to plans A, B and C. See the
related Instruction book.
6. Switch on the voltage and scroll to the service screen shown
in Fig. 15.2. Press the Rset button (F3) to reset the timer.
Confirm the question for resetting.
Notes
- The Rset button only appears when the next Timer level
is almost reached (from 400 running hours before elapsing
of the service plan interval).
- After pressing the ¯ key in Fig. 15.1, the Life time hours
are shown (i.e. the number of hours elapsed since initial
programming ex-factory). This counter is not taken into
account.
16 Saved data menu
Function
To call up some compressor data saved by the regulator. These
data are:
- Last shut-down data
- Last emergency stop data
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Saved data is followed
by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. The list of last shut-down and emergency stop cases is
shown.
3. Scroll through the items to select the desired shut-down or
emergency stop item.
4. Press the tabulator key (5) to find the date, time and other
data reflecting the status of the compressor at the last shut-
down occurred.
52237F
8
11
710
612
3
2
1
9
4
5
4
9
S3