2920 1461 03
29
User manual
14 Configuration menu
Function
To reprogram a number of parameters. See Figs. 3.1.
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Configuration is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is Time.
If another option is desired, scroll through the display (using
¯ or keys) and select it using the tabulator key (5).
4. In case of option Time, the second line on the screen
indicates the actual setting, e.g. 14:30.
5. If it is desired to modify the time, press the key Mod. If
not, press the key Menu to return to the submenu.
6. After pressing the key Mod, the first field (14) will blink.
Modify the hours using the ¯ or keys. Then press the
tabulator key (5) to go to the next field (i.e. 30). The setting
of this field can now be modified with the ¯ or keys.
7. The bottom line of the display will show two options:
- Prog to program the new setting
- Canc to cancel the new setting
8. Proceed in a similar way for the other parameters to be
modified.
14.1 Programming compressor control
modes
Compressor control modes
The compressor can be controlled locally, remotely or via a
local area network (LAN). See the related Instruction book,
section 3.2.
Procedure
1. Starting from the Main screen (see section 3.2):
- press the key Menu (F1)
- press the ¯ key until the option Modify params is
followed by a horizontal arrow
- press the tabulator key (5) to activate the menu
2. Use the ¯ key to scroll until the option Configuration is
followed by a horizontal arrow.
3. Press the tabulator key (5): The first option shown is Time.
Scroll through the display (using ¯ or keys) until the option
CCM is followed by a horizontal arrow and select it using
the tabulator key (5). Following screen is shown:
CCM
Local control
Menu Mod ¯
F1 F2 F3
Fig. 14.1 Compressor control mode menu
4. Press the key Mod and use ¯ or keys to select the desired
control mode. Press the Prog key to program or the
Cancel key to cancel the modification.
15 Service menu
Function
- To reset the service plans which are carried out.
- To check for both the next service plans to be carried out
and to find which service plans were carried out previously.
Service plans
- Consult the related Instruction book to find which service
actions are related to these plans.
- Consult section 12 if any modification to the intervals should
be required.
When the service plan interval is reached, a message will appear
on the screen. See section 5.
Example
Programmed service plan intervals ex-factory
Service plans Intervals
Service plan A Each 4000 running hours
Service plan B Each 4000 running hours
Service plan C Each 8000 running hours
Service plan D Each 40000 running hours
Resulting service actions to be carried out
Service actions according to At
Service plan A and B 4000 running hours
Service plan A, B and C 8000 running hours
Service plan A and B 12000 running hours
Service plan A, B and C 16000 running hours
.