CHAPTER6 Hardware Maintenance
Mediant 1000 Gateway & E-SBC | Hardware Installation Manual
4. From your local computer, access the device's Web interface with the device's default IP
address (192.168.0.2/24), through the GE 0/1 or 0/2 Ethernet port on the CRMX module.
5. Load the software file (.cmp) to the device. If you don't have the file, ask your AudioCodes
sales representative for it.
6. Load the License Key file to the device.
7. Load your backup (saved) Configuration Package file or individual files (e.g., ini file,
certificate files, Dial Plan file, and CPT file), if you have, to the device.
8. Check that the required certificate is installed on the device (TLS Context). If not, load it.
9. Disconnect your computer from the device, and then connect the device's Ethernet port to
your network.
10. Verify that the device is operating correctly (e.g., alarms are cleared and call traffic is being
routed) and that it is successfully communicating with third-party equipment (e.g.,
monitoring system, billing system, or routing system), if relevant.
11. If the device is monitored by OVOC, access the OVOC web-based management interface,
remove the device from the OVOC topology, and then re-add it.