J-16
CX Series
Function setting mode
1: In case of free voltage input model (
CX6 - F)
, these parameters do not appear due to xed setting.
2:
This parameter is for the voltage input(PNP)/no-voltage input(NPN) selectable model (CX6 - ).
: When changing the setting of shaded parameters, all output turn OFF.
RUN mode
3 sec
Min. reset time
1
[
R
ESET
]
Input logic
1
[
SIG
]
TOTAL counter
2
[
TOTAL
]
Memory protection [
DATA
]
Key lock [
LOCK
]
Input mode [
I
nM
]
Counter/Timer [
C-T
]
Output mode [
OUt
M
]
Max. counting speed
1
[
CPS
]
OUT2 output time [
OUT2
]
OUT1 output time [
OUT1
]
Decimal point [
DP
]
Prescale value [
SCL
]
Start Point value [
START
]
Prescale decimal point [
SClDP
]
3 sec
OUT output time
[
OUtT
]
Function setting mode
Function setting check mode
(only for free voltage input model (
CX6
-
F))
-When checking the saved parameters, press the , key to check next item.
- At function setting check mode, the counting value display component displays the parameters and the setting value display
component displays the SV of the parameters.
Checking SV of TOTAL counter
- At TOTAL counter operation, the counting value display component displays the current value and the setting value display component
displays TOTAL counter counting value.
When TOTAL counter counting value is over 999999, it counts from 0 again.
Switching display of the setting value display component
(only for voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - )
- In case of 2-stage setting model(CX6
-
2P ), whenever pressing the key, each SET2, SET1, TOTAL COUNTER value
displays consecutively.
Display HOLD output mode for counter
-
It displays the over value of prescale value.
-
When SV is n multiplied by prescale value and the display value after HOLD output mode and
SV are different, the prescale value is not the 1/n time of SV.
RESET
-In RUN mode, function setting mode, press the
RESET
key to reset the current value and the output turns OFF.
- At TOTAL counter display mode, press the
RESET
key to reset TOTAL counter counting value and the current counting value.
- Hold the key over 3 sec in RUN mode and it enters
function setting mode.
- Hold the key over 3 sec in function setting mode
and it returns to RUN mode.

Other manuals for Autonics CX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autonics CX Series and is the answer not in the manual?

Autonics CX Series Specifications

General IconGeneral
BrandAutonics
ModelCX Series
CategoryTimer
LanguageEnglish

Related product manuals