J-16
CX Series
● Function setting mode
※
1: In case of free voltage input model (
CX6 - F)
, these parameters do not appear due to xed setting.
※
2:
This parameter is for the voltage input(PNP)/no-voltage input(NPN) selectable model (CX6 - ).
※
: When changing the setting of shaded parameters, all output turn OFF.
RUN mode
3 sec
Min. reset time
※
1
[
R
ESET
]
Input logic
※
1
[
SIG
]
TOTAL counter
※
2
[
TOTAL
]
Memory protection [
DATA
]
Key lock [
LOCK
]
Input mode [
I
nM
]
Counter/Timer [
C-T
]
Output mode [
OUt
M
]
Max. counting speed
※
1
[
CPS
]
OUT2 output time [
OUT2
]
OUT1 output time [
OUT1
]
Decimal point [
DP
]
Prescale value [
SCL
]
Start Point value [
START
]
Prescale decimal point [
SClDP
]
3 sec
OUT output time
[
OUtT
]
Function setting mode
● Function setting check mode
(only for free voltage input model (
CX6
-
F))
-When checking the saved parameters, press the , key to check next item.
- At function setting check mode, the counting value display component displays the parameters and the setting value display
component displays the SV of the parameters.
● Checking SV of TOTAL counter
- At TOTAL counter operation, the counting value display component displays the current value and the setting value display component
displays TOTAL counter counting value.
※
When TOTAL counter counting value is over 999999, it counts from 0 again.
● Switching display of the setting value display component
(only for voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - )
- In case of 2-stage setting model(CX6
-
2P ), whenever pressing the key, each SET2, SET1, TOTAL COUNTER value
displays consecutively.
● Display HOLD output mode for counter
-
It displays the over value of prescale value.
-
When SV is n multiplied by prescale value and the display value after HOLD output mode and
SV are different, the prescale value is not the 1/n time of SV.
● RESET
-In RUN mode, function setting mode, press the
RESET
key to reset the current value and the output turns OFF.
- At TOTAL counter display mode, press the
RESET
key to reset TOTAL counter counting value and the current counting value.
- Hold the key over 3 sec in RUN mode and it enters
function setting mode.
- Hold the key over 3 sec in function setting mode
and it returns to RUN mode.