Assembly
Mono Power Unit BUM 62 T 19
Baumüller Nürnberg GmbH 5.99009.03
5 ASSEMBLY
5.1 Free space
*
The total depth depends on the controller dimensions!
WARNING
The user is responsible for the assembly of the unit described, the motor, and the other devices
according to the safety regulations (e.g. EN, DIN, VDE) and all other relevant nations or local
regulations concerning the conductor ratings and protection, grounding, disconnectors, overcurrent
protection, etc.
The following measures for ventilation must be strictly observed.
Otherwise, the unit may be overheated.
y Ensure sufficient cooling air and ventilation!
y Ventilation must be from the bottom to the top, ensure a free space above and below the unit (see
”Free space” on page 19).
y The rated power of the unit is possible only up to a specific ambient temperature! The power must
be reduced when higher temperatures occur (see
”Table of technical data” on page 13).
y Do not locate any other sources of heat above the unit.
y Pollution degree 3 and 4 according to EN 50178:1994 Section 5.2.15.2 must be avoided. The units
are suitable for the installation in closed operating rooms. (VDE 0558 Part 1a, Section 5.4.3.2.1 and
5.4.3.2.2)