Home
Baur
Test Equipment
Syscompact 2000
Baur Syscompact 2000 User Manual
5
of 1
of 1 rating
32 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
21
4.4
Switch high voltage on and off
4.4.2
HV on
Press main swi
tch, green lamp lights
Regulating transforme
r to left limit stop
and emergency off not pressed
Press “
high vo
ltage ready
”, red lamp li
ghts
Press “
high vo
ltage on
”, button and red la
mp lights
20
22
Table of Contents
Default Chapter
5
Table of Contents
5
1 Application
6
2 Theory of Cable Fault Prelocation
7
Echometer (Time Domain Reflection)
7
Secondary Impulse Method
8
Impulse Current Method (ICM)
10
3 Arrangement of Instruments Within the System
11
Front View
11
Rear View
12
Sa 32 K
13
High Voltage Socket Board CS
13
Cable Drum Rack KTG M3
14
Connections / Operation of IRG 2000
15
4 Using the Syscompact 2000
16
Important Notices
16
Discharge- and Grounding Rod
16
Connecting the Syscompact 2000
18
Connection to Different Cable Types
20
Switch High Voltage on and off
21
HV on
21
HV off
22
5 High Voltage Testing
23
6 Cable Fault Prelocation Methods
24
Prelocation with TDR (Time Domain Reflection)
24
Sim - MIM
25
Application SIM - MIM with DC Voltage (SIM DC)
26
Impulse Current Method (ICM / Surge Method)
28
7 Accurate Fault Location (Pin Pointing)
29
8 Technical Data
30
9 Maintenance
31
Adjustment of Spark Gap
31
Checking Discharge Unit
31
10 Accessories & Options
32
External Emergency Switch-Off (Option)
32
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Baur Syscompact 2000 and is the answer not in the manual?
Ask a question
Baur Syscompact 2000 Specifications
General
Brand
Baur
Model
Syscompact 2000
Category
Test Equipment
Language
English
Related product manuals
Baur DPA 75
68 pages
Baur DTA 100 C
90 pages
Baur PGK 80
38 pages
Baur PGK 70 HB
34 pages
Baur PGK 25
24 pages
Baur PGK 50
38 pages
Baur PGK 110 HB
34 pages
Baur PGK 150 HB
34 pages
Baur KSG 200 A
60 pages